Isol8

Isol8 MiniSub Wave

Power cable

Isol8 MiniSub Wave filtered mains distribution block, fitted with six outlets split between low/medium current and high current circuits, for powering an entire hi-fi or home cinema system.

On request 2 245,00 €
Guaranteed & tested Equipment checked by the merchant
Returns accepted 14 days to change your mind

Description

The Isol8 MiniSub Wave is a filtered mains distribution block, designed to power the various links of an audio system from a single point. Its purpose is not merely to multiply the number of available outlets, but to treat the quality of the current reaching each device, taking into account the fact that a system brings together equipment with very different electrical behaviours.

Its architecture is based on that of the MiniSub Axis, to which Isol8 adds complementary filtering stages. The distribution is split into two distinct domains: on one side, four outlets reserved for low or medium consumption devices, and on the other, two outlets sized for high currents. This separation addresses a concrete problem, that of cross-contamination: a device that feeds noise back onto the line disturbs its neighbours plugged into the same strip.

To address this, each of the four outlets intended for low and medium currents has its own filter, employing the Transmodal technology developed by the brand. Filtering is therefore not shared across the whole unit but applied outlet by outlet, allowing devices to be electrically isolated from one another. The two high-current outlets, meanwhile, are treated by a newly designed high-performance filter, suited to significant current draws without restricting dynamics.

This type of configuration suits complete installations, where digital sources, players, preamplification and power amplifiers coexist. Sources, particularly sensitive to common-mode and differential noise, find their place on the individually filtered outlets, while amplification benefits from the high-current line. This is a solution that will appeal to listeners who already have an established system and are faced with a degraded domestic electrical network, or one shared with polluting loads.

What to check before buying used

Test each outlet under real load, particularly the two high-current outputs: a worn internal contact or relay can cause micro-cuts that are difficult to detect with no load applied. Also check that the earthing and original mains cable are intact, as well as the condition of the terminal block and internal fuses. Finally, a unit that has experienced a surge or lightning strike may have damaged Transmodal filtering stages without this being visible from the outside.

Currently unavailable

Looking for this reference: MiniSub Wave ?

Tell us what you are looking for: our merchants are notified, and one of them may have it in stock.